Guide

Preparation guide by material

Reduction and margin guidelines for each material.

For: the dentist preparing the tooth.

Adequate reduction and a clearly defined margin are the main factors in the fit, strength and appearance of the final restoration. The values below are general guidelines. For atypical cases, call the lab before preparation.

Before you prepare

  • Select the material first. It determines how much reduction is needed.
  • Take the shade before the tooth dehydrates.
  • Take a pre-operative scan or impression if the restoration should reproduce the existing tooth form.

Minimum reduction by material

Our ceramic restorations are made from Ivoclar materials: IPS e.max Zirconia and IPS e.max lithium disilicate. Rows marked "Ivoclar" give the manufacturer's published minimum thickness for the finished restoration, so reduce at least that much; the others are general guidelines. Additional reduction improves esthetics.

RestorationOcclusal or incisalAxial wallsMarginSource
Zirconia crown (IPS e.max Zirconia)0.7 mm minimum posterior; 0.6 mm anterior0.7 mm minimum posterior; 0.6 mm anteriorShoulder with rounded inner edges, or chamfer at about 10 to 30 degreesIvoclar
Zirconia 3-unit bridge abutment0.8 mm minimum0.8 mm minimumShoulder with rounded inner edges, or chamfer at about 10 to 30 degreesIvoclar
Zirconia bridge with two pontics between abutments1.0 mm minimum posterior; 0.8 mm anterior1.0 mm minimum posterior; 0.8 mm anteriorShoulder with rounded inner edges, or chamfer at about 10 to 30 degreesIvoclar
Zirconia anterior bridge with three or four pontics1.0 mm minimum1.0 mm minimumShoulder with rounded inner edges, or chamfer at about 10 to 30 degreesIvoclar
Porcelain fused to zirconia1.5 to 2.0 mm1.2 to 1.5 mmChamfer or rounded shoulder, 1.0 mmGeneral guideline
e.max crown, adhesively cemented (IPS e.max lithium disilicate)1.0 mm minimum1.0 mm minimumShoulder with rounded inner edges, or chamfer; at least 1.0 mm wideIvoclar
e.max crown or partial crown, conventionally or self-adhesively cemented1.5 mm minimum1.5 mm minimumShoulder with rounded inner edges, or chamfer; at least 1.0 mm wideIvoclar
e.max inlay, onlay or occlusal veneer1.0 mm minimum1.0 mm minimumNo feather edges; butt joint or rounded shoulderIvoclar (thickness)
e.max veneer1.0 to 1.5 mm where the incisal edge is reduced (general guideline)0.3 mm minimum facialLight chamferIvoclar (facial thickness)
Zirconia veneer1.0 to 1.5 mm where the incisal edge is reduced (general guideline)0.5 mm minimum cervical and facialMargins in enamel where possibleIvoclar (facial thickness)
Zirconia inlay or onlay0.5 mm minimum depth; 1.0 mm in the cusp areasIsthmus at least 1.0 mm wideNo slice cuts or feather edgesIvoclar
Porcelain fused to metal1.5 to 2.0 mm1.2 to 1.5 mmChamfer; shoulder where porcelain meets the marginGeneral guideline
Full metal crown1.0 mm0.5 to 0.8 mmChamfer or knife edgeGeneral guideline

The 1.0 mm e.max crown is indicated by Ivoclar only with adhesive cementation and a composite build-up. Ivoclar lists bruxism, bridges and implant crowns as contraindications for that reduced thickness.

e.max veneers, inlays, onlays and occlusal veneers are cemented adhesively. Ivoclar indicates e.max bridges for three units, with the second premolar as the most distal abutment; for longer or posterior spans, choose zirconia.

Preparation design

  • Prepare no sharp angles or edges. Round all internal line angles and transitions so stress does not concentrate in the ceramic and the form can be milled accurately.
  • Reduce the anatomical shape evenly, observing the minimum thickness throughout.
  • For conventional or self-adhesive cementation, Ivoclar recommends a retentive preparation: a preparation angle of about 4 to 8 degrees and a preparation height of at least 4 mm.
  • Prepare a continuous, smooth and clearly visible margin.
  • Avoid gutter or J-shaped margins, feather edges on glass ceramics, and shoulders with sharp internal corners.

Confirm clearance before the final scan or impression

  • Check occlusal clearance with the patient in maximum intercuspation and in excursions, using a reduction guide, bite registration material or the clearance tool in your scanner.
  • If clearance is limited, note on the Rx whether you prefer a call, adjustment of the opposing tooth, or a reduction coping.

Bridges

  • Prepare abutments with a common path of insertion.
  • Allow connector height. Ivoclar notes that connector height matters more than width for strength, so short clinical crowns limit the span that can be restored predictably.
  • Ivoclar does not indicate IPS e.max Zirconia for posterior bridges with more than two connected pontics, or anterior bridges with more than four.

Manufacturer references

Values marked "Ivoclar" on this page are taken from Ivoclar's published documentation. Refer to the current documents for complete instructions.

Request information

Complete the form and a member of our team will respond within one business day.

Or call 484-891-1071.

TDB Dental Lab
301 S. Main St, STE 2S
Doylestown, PA 18901
Monday to Thursday, 9am to 5pm

Provide a phone number or an email address. It is used only to respond to this request.

A member of our team will respond within one business day. To speak with us now, call 484-891-1071.